Potter
SKU: PAM-4
Potter PAM-4 Polarized Relay Module
Polarized relay module for access control and door strike switching
Overview
Manufacturer-verified compatible cameras, recorders, mounts, accessories, and licenses for this product. Adjust quantities and add the entire bundle to your cart in one click.
Overview
Questions about this product? Free pre-sales support from a senior specialist — product questions, compatibility checks, BOM quotes, price confirmation — typically answered within one business day. Need camera placement or system design work? Engineering time is $175 per hour (qty 1 = 1 hour). Hardware buyers get up to one hour ($175) credited back on their order.
The Potter PAM-1 is a compact, pre-wired relay module designed for integration into security system control circuits. It accepts multi-voltage input (polarity-sensitive with diode protection) and provides 10.0-ampere form-C (SPDT) relay contacts. The module ships with six pre-terminated 18 AWG flying leads, six wire-nuts, mounting hardware, and an adhesive backing option — everything needed for fast installation in a control cabinet or enclosure.
If your security system architecture requires auxiliary relay logic to trigger door locks, solenoids, strobes, or alarm outputs, the PAM-1 delivers straightforward, UL864-rated switching without the overhead of a larger control panel. The single red LED indicates coil energization at a glance, reducing troubleshooting time in the field.
The PAM-1 integrates into any control system that provides a voltage-regulated coil signal—fire alarm panels, security control loops, access-control relay outputs, or even a network video recorder output card (if equipped with relay control). Wire the coil leads to your control signal; connect the SPDT contacts to your load circuit (door lock, strobe, solenoid, etc.). Confirm voltage compatibility and load current before installation.
For multi-relay logic architectures, consider how many PAM-1 modules you'll need and whether your control power supply has enough regulated 12V or 24V capacity. A dedicated power supply rated for all coil currents is recommended if driving many modules simultaneously.
Operating temperature range is 32°F to 120°F (0°C to 49°C). This suits standard indoor control cabinets and utility rooms but not unheated outdoor kiosks or extreme environments. If your enclosure will see temperatures below freezing or above 120°F, confirm the environment or implement cabinet heating/cooling.
Q: Can the PAM-1 switch 120VAC loads directly?
A: The relay contacts are rated for 10A and can switch 120VAC circuits. However, confirm your specific load current and voltage against the datasheet. For high-inrush loads (motor starters, transformer primaries), an external contactor is safer.
Q: What happens if I wire the coil input in reverse polarity?
A: The internal diode protection prevents damage, but the relay will not energize. Always match the polarity markings on the module during installation to ensure reliable operation.
Q: Can I use the PAM-1 in a UL-listed fire alarm system?
A: Yes. The PAM-1 carries UL864 certification and must be installed in accordance with NFPA 70 (NEC). Consult your system integrator or fire alarm design engineer for proper circuit integration and documentation.
Q: What's the maximum coil current draw?
A: The datasheet specifies input operating characteristics; consult the PDF for exact coil current specs to ensure your control power supply is sized correctly.
Q: Can I mount the PAM-1 in a vertical or tilted position?
A: Yes. The compact form factor and modular design allow wall, DIN-rail, or adhesive mounting in any orientation. Ensure the adhesive or screw connection is secure and won't vibrate loose.
Q: Is the PAM-1 suitable for outdoor use?
A: No. The module lacks an IP rating and is designed for indoor control cabinet use only. If outdoor relay switching is required, consider an outdoor-rated enclosure or a weather-sealed relay module.
The Potter PAM-1 (often searched as PAM 1) is a straightforward, no-nonsense relay module for control circuits where you need a single auxiliary switch rated for 10 amperes. Its UL864 certification and diode-protected multi-voltage coil design make it a reliable choice for fire alarm, security, and access-control integration—but only if your load current actually fits within the 10A limit and your enclosure stays between 32°F and 120°F.
Technical Highlights:
Deployment Considerations:
The PAM-1 is a solid fit for auxiliary relay switching in fire alarm control loops, access-control output circuits, or security panel expansion—anywhere you need a compact, certified 10-amp relay with flying leads and no fuss. Skip it if your load exceeds 10A, your enclosure runs outside 32–120°F, or if you need multi-pole relay logic (use a larger panel or relay board). For single-channel, low-current auxiliary switching in a standard indoor control cabinet, it's reliable and cost-effective.
Manufacturer-verified compatible cameras, recorders, mounts, accessories, and licenses for this product. Adjust quantities and add the entire bundle to your cart in one click.
Support services and planning resources for commercial surveillance, access control, and infrastructure deployments.